Initial HyperX Eve 1800 SignalRGB plugin and protocol tools
Working 10-zone plugin using the 0x44 live colour reports on the 0xFF90 vendor interface (data then commit). Includes Python tools used to identify the device, confirm the protocol and map zones. Output is dimmer than onboard effects; investigation pending. Co-Authored-By: Claude Opus 5.5 <[email protected]> Claude-Session: https://claude.ai/code/session_01EcbUcbNpyPn7cGpe4t6y5y
This commit is contained in:
commit
5f36610a60
11 files changed
+491
No files matched your search
@@ -0,0 +1,24 @@
|
||||
"""Dump + decode the HID report descriptor of the vendor interface (read-only)."""
|
||||
import hid
|
||||
|
||||
VID, PID, USAGE_PAGE = 0x03F0, 0x08C2, 0xFF90
|
||||
|
||||
info = next(d for d in hid.enumerate(VID, PID) if d["usage_page"] == USAGE_PAGE)
|
||||
dev = hid.device()
|
||||
dev.open_path(info["path"])
|
||||
desc = bytes(dev.get_report_descriptor())
|
||||
dev.close()
|
||||
|
||||
print(f"{len(desc)} bytes: {desc.hex(' ')}\n")
|
||||
|
||||
TAGS = {0x04: "UsagePage", 0x08: "Usage", 0xA0: "Collection", 0xC0: "EndCollection",
|
||||
0x14: "LogicalMin", 0x24: "LogicalMax", 0x74: "ReportSize", 0x94: "ReportCount",
|
||||
0x84: "ReportID", 0x80: "Input", 0x90: "Output", 0xB0: "Feature",
|
||||
0x18: "UsageMin", 0x28: "UsageMax"}
|
||||
i = 0
|
||||
while i < len(desc):
|
||||
prefix = desc[i]
|
||||
size = {0: 0, 1: 1, 2: 2, 3: 4}[prefix & 3]
|
||||
val = int.from_bytes(desc[i + 1:i + 1 + size], "little")
|
||||
print(f" {TAGS.get(prefix & 0xFC, f'0x{prefix:02X}'):14} 0x{val:X}")
|
||||
i += 1 + size
|
||||
Reference in new issue